what is the advantage by using PID controller than P& PID?
Answer Posted / bunny
By using a PID controller we can eliminate the offsets and
unwanted oscillations of the process variables we are
dealing with and will get the process variable value close
to the set point value.For that we need to tune the
controller properly and select proper values for P,I and D
| Is This Answer Correct ? | 6 Yes | 1 No |
Post New Answer View All Answers
What is zero elevation and zero suppression?
WHAT IS THE CAM POSITION IN CONTROL VALVE POSITIONER ? WHY IT IS USED?
what is function of switch, and how is it work, explain with difination
Describe the function of Accumulator into the Pump
What is the basic difference between Modbus and CAN Open Protocols
How earthing can be checked????
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
How does temperature bath work? How does coil gets heated only by applying some current?
How to interfacing microcontroller with a DC motor
Conversions
HI, can anybody give details about GAS TREATMENT PLANT CONSTRUCTION,as INSTRUMENTATION ENGINEER what are the responsibilites.what are the instruments mainly instrumentation engineer will deal with
what is the reason while warning lamp is on while the engine is cranking?
Hi Friends i am going to write BARC written test by this month 20th (20-5-2008). So please if any body knows the details about this or having previous question papers pls mail me to kkumarei@gmail.com. For Suggestions give one message to 9962122264
For what reason would you possibly be compelled to make use of a Smith Predictor. Explain the idea behind the operation of this device.
How r the calculation of process line mpm.