what is the safety of ACB & VCB and how can this work and
how can the service the ACB & VCB parts name with picture

Answer Posted / rajesh verma

As you all knows that all circuit breakers can be called
as on off switch with some safety device ie ACB make and
break contact in air (one moving and one sliding) so it
called air circuit breaker for safety we use in ACB Under
voltage shunt trip closing unit. CBCT for tripping command
relay with over voltage earth fault etc for spring charge
we use motor charging mechanism. Same case with VCB
contacts makes in vacuum to minimize the arc during make
and break contact (one moving and one sliding) on high
voltage other function are same but according to the
voltage rating

Is This Answer Correct ?    121 Yes 24 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Can RCD's used to protect the VVVF drive if not why.

1710


what is the breaking capacity and making capacity of circuit breaker and how

1581


How can you sized or estimate the ligthning arrester current rating?

1601


What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer?

1533


i am completed in B.E(Electrical and Electronics Engineering) with 8 months experience in Quality Control Engineer at Bharathi Industries,Coimbatore.

1466






Mr. mohh sahid m not satisfied for ur answer to the que weather the size of transformer increases or decreases withchange in fr for more detail go to the answer given by me

1616


What is the minimum value of hfe for the oscillations in transistorized rc phase shift oscillator?

758


can i connect REF and Differencial relay in 1 CT core for transformer protection?

1459


any one can explain the stages of a knee point which is taken during ct magnetising curve.

1311


What are the factors which influence the choice of specific magnetic and electric loadings of a synchronous machine?

1587


i ha done my 10th with 71% ,ITI with 81% 11th with 75% 12th 43% apprentiship with 71% in SAT i secure 1390 ,TOEFL 27 i was refused four times and in all me interview visa officar told that i am not Qualify for study in USA but i completed my 12th yes i got low persentage in my 12th but i seen to much student they already got visa with them 3 or 4 backlocs so why they are refused me ?

3051


1.What is the range of stator resistance of 3-phase induction motor? 2.Two electrically operated vibro motors are foxed in parallel direction in vibrating feeders. what is the direction of both vibro motors?

1445


how to carried out DAR test in 11 KV Alternator ?

1837


why Induction Generators are not "Black start" ? and apart from WTGs where this types of generator are generally used?

2213


What is the vector group of a transformer,how can it be found out?

1562