can we change the range of 3151 model level transmitter of
rosemount make? present calibration range is 1000mmwc and
want to change it to 2000mmwc
Answer Posted / mudassir
yaa you can but you have check the model no. if it is30512G
THEN YOU CAN CALIBRATE IT upto6000mmwc
Is This Answer Correct ? | 0 Yes | 1 No |
Post New Answer View All Answers
the pump holds on run indication into the dcs and filed local control panel remote push button condition operaton wrong like when the push button pushing conditions the pump is off and the push button release condition the pump is on totally opposite condition . And control room inside give the stop command into dcs just 1secon relay engage and again normal condition. How can I slove
Hi i am aneesh, done btech in applied electronics & instrumentatiin. And then i took mba in finance & marketing.After that i got placement in finance co and worked there for 3.5 yrs.Now i wanted to come back to engineering job.But without engg experience, i may not able to find an opening.i have done a course related to flow meters and ite calibrations. Kindly suggest where should i try to get a job?
hiii.... can any one provide me previous years question paper of hindustan petroleum for instrumentation engineering???
how to convert MA in to measuring values..and how mwasuring values into MA ?..plz ansr.i have intervw
in which principle pressure tx,level tx ,flow tx,temp tx ,control valve works?
why we use cascade control and feed forward control in 3 element drum level control measurement of steam drum .what is cascade and feed forward control system ?give example .
How we connect a instrument with ground, Give brief explanation with help of diagram?
I m appointed as an automation trainee engineer in small firm in that I am only the one , my company give me a project on s7-200 as i m beginner I don't know how to program so please send me the helpful site so that I complete my project before deadline....please help me out in this critical situation.
please send the drdo exam paper
Draw a P& ID showing – orifice flange, plate, dp transmitter, isolation & bypass valves and tubing.
draw the block diagram of a level transmitter ?
Hi Friends i am going to write BARC written test by this month 20th (20-5-2008). So please if any body knows the details about this or having previous question papers pls mail me to kkumarei@gmail.com. For Suggestions give one message to 9962122264
How will you test a transistor with a multimeter?
Gas equation
it is possible to check the fail safe condition in pressure transmitter. if possible how?