In RTU Panel we are having several Analogue & Digital
Inputs /Outputs. We are recently facing some problems over
Analog inputs , which are not updating properly (But
Digital Input are updating normally) Can any one tell me
from where the problem is creating , we have checked PLC
CPU card, Analog Input card & we reconfigured ,But still
the issue is there.
Issue :
1. Sometimes Analog values are updating & sometimes not.
2. Analog values are not updating normally , showing some
wrong Values
3. Total dead (0 value)
Analog values are Level & flow measurement from the field
instruments.
(But in field the instruments are working normally &
Displaying the values normally in local display unit)
This problem we are facing in our Water Plant.
If any one experienced this same problem or having any
ideas related to our issue PLS send your valuable
Answers/Replies...
Answer Posted / mudassir
hiiiiii this is because of scaling of input cables in the MR
side or your analog chanel are hang if you remove the
connection and connect it again then it shows normal den its
your analog card has a problem.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
when placing a vent or drain hole on an orifice plate should you measure from the center of the bore up or down for the vent placement?
In a gas over oil actuator, after the opening/closing of valve, how the gas is vented out? How does the hydraulic/gas circuit function?
need to calculate flow rate with the help of dp range and orifice bore dia and size. range is 0 to 400 inwc and orifice size is 12 inch 150 # rf and bore dia is 7.180 inch. need to calculation for flow rate
In turbine, what does term CDP, NI, NH, HSSOC, means
how can leve transmetter calibate in feild .and also put cv and flow plz .....
What is wet leg condition and why is it used?
draw the block diagram of a level transmitter ?
how can be calibrate flow indication transmitter (rosemount) it shows excess milli amps nearly about 24 ma on full scale, but its scale was set on 20ma on full scale..???how can be simiulate..???
what does it mean an active front end in vfd plz explain it briefly
Explain plc level and its type?
Instrumentation Safe Guarding test. How to determine the interval time of the test. eg:Halfyearly,Every year,Every three years etc.
Explain PID, ON/OFF, Controls
Give 2 application of quartz crystal used for process parameter measurement.
what is the working principal of pribe
what is o2 analyzer and how it measured ,what is the role of this analyzer in cfbc boiler...