an off load but energized 11/0.4 KV, 1250 KVA T/F has a
power factor of 0.65(capacitive)..!! why is it so, though
T/F being an inductive device ??
Answer Posted / ahmad yousuf
need answers from T/F specialists..!!
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
why we use sinosidal voltage / current instead of others in system?
i have some screw comprressor with 630kw power,i have established them with simple star to delta circuit,by the way there is so much inertia when the screw comprressors start, can you offer me contactors power with 400vac or any cataluge to choose the contactors
A cylindrical wire is compressed in length by 10%. The percentage decrease in the resistance will be?????
how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating)?
Why syn. Generators are used for the production of electricity?
what is a bus post insulator? explain its application in a substation.
What is rotating magnetic field?Discuss elaborately.
What is force on parallel conductors ?
11000volt DG set carnt kaise banvay
what is meant by 2 within a star in a voltmeter dial?
Can any answer me ,What will be the range of C.T coil for L&T energy meter EM301 used for 180 kva DG set
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.
Which cable is use for rtcc control panel
difine electrical ballast in HPSVL
What are the basic elements used for modeling mechanical rotational system?