What is the difference between a Extension cable and a
copnesating cable.Where can we use compensating cable.
Is anywhere compensating cable are used for
mv transmission to the indicator.
Answer Posted / rathna
I thing this question belong to Thermocouple.Extension
cable means What we used for T/C's the same cable extern
untill the converter or Transmitter.Compensating cable
means Equal character Cable is used untill converter or
transmitter
| Is This Answer Correct ? | 1 Yes | 4 No |
Post New Answer View All Answers
why Fahrenheit unit of moistur analyzer transmitter
Sir , i have completed my M.Sc In Instrumentation and presently working in Maintenance department 3 yrs Exp , is there is any possible for work in offshore ..
How many interlocks at turbine? Plz explain briefly
in which principle pressure tx,level tx ,flow tx,temp tx ,control valve works?
what is the field bus calble ? what are diffrences in orang colur cable and black coular calble ?
Good evening all I need a small favour regarding reliance paper i wanna probable sample papers(e&i) of reliance. if any of u have any idea about dis then plz mail me back.i belongs to electronics and instrumentation engg.so i need e&i papers. thanking u....
what is the calibration procedure for transweigh make weigh feeder?
Can please tell mi about SIOS, PRM, SERVER, and what is the diference between PIN LAN, PCS LAN,APC Server, and please send the Doc if possible for referance,mail id patil_amit17@yahoo.com
What are the maximum packet size of: a) HART b) Profibus DP c)Profibus PA d) DeviceNet e) Foundation Fieldbus
What is PDS and PDMS ?
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
what are the steps I have to deal with?
How do you identify an orifice in the pipeline?
What are different type of instrument cable
what is sliding spool valves?