Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

In RTU Panel we are having several Analogue & Digital
Inputs /Outputs. We are recently facing some problems over
Analog inputs , which are not updating properly (But
Digital Input are updating normally) Can any one tell me
from where the problem is creating , we have checked PLC
CPU card, Analog Input card & we reconfigured ,But still
the issue is there.
Issue :
1. Sometimes Analog values are updating & sometimes not.
2. Analog values are not updating normally , showing some
wrong Values
3. Total dead (0 value)
Analog values are Level & flow measurement from the field
instruments.
(But in field the instruments are working normally &
Displaying the values normally in local display unit)
This problem we are facing in our Water Plant.
If any one experienced this same problem or having any
ideas related to our issue PLS send your valuable
Answers/Replies...

Answer Posted / rakesh kumar n

Reasons for this problem

-->In I/P there will be a problem in microprocessor,because
we use microprocessor for converting it into mA.

-->Check with another I/P,if you find the same problem,then
definitely cable Fault(loose contact in JC)

-->Check the loop test between the Junction box and Field
Instrument if it is correct, then check Junction box to
Control room is correct.

Thank you
Rakesh Kumar N

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is Cavitation in a control valve?

1994


How do you identify an orifice in the pipeline?

1181


please send the drdo exam paper

2332


what are the diff. in servo and regulatory control?

3908


I am having a Phoenix digital to modbus converter. The o/p of the same is connected to flow computer FB407. But the digital signals are updated only after one minute in the flow computer. what may be the cause of delay in communication? Flow computer is having a scanning period of less than 1 sec.

1833


Square root calculation for dp flow transmitter?

1159


IN CONTROL VALVE SPECIFICATIONS GENERALLY TERM " DE- 200" ."DM -400"USED,, WHAT IS DE/ DM STANDS FOR?

2167


How can measure flow in oil line?which type of transmitter is generally used?

4117


Positioner usage.

1875


hii my name is sujith...i am preparing for HPVL GET 2010... so ,,,pls help me by send any previous questions or material to my site.....(Msujith_12@in.com) thank q

1828


For crude application in floating roof tank, how to calibrate a DP Transmitter? How is the floating roof weight considered?

3066


Differentiate between ultrasonic flowmeter and radar type flow meter

1156


how pressurize drum calibrated ?

1972


What is 3 selection available when configure the burnout protection for controller

2642


Hook up resistance decade box to temp.transmitter.

2188