Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is bus post insulator and its applications in
substations

Answer Posted / shibuss

bus post insulator is a stack of insulator and used in
locations where minimum ground clearance of live conductor
can not be maintained

Is This Answer Correct ?    26 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why LED light has advantage of rapid reflection ,although other lights alse reflect.? and this light is considered to be best for transmission usage in case of Free optics

2025


what are the maximum available current, voltage ratings and switching speeds of the power electronic devices thyristor, power mosfet, igbt, and mct?

2081


for 100 HP Induction motor service factor is 1.2(SF) we placed a VFD at the motor side load is balance with 0.3 Amp's Phase to Phase but at incoming of VFD load is un-balance with 10 to 20 Amp's what will be cause of load un balance

1932


hi friends how 3 phase converter functioning ?what is working principle of rotory phase converter ?

2069


Explain M Var? Which types of problem occurs when reactive power increase at the time of full load of plant and at the time of synchronize of plant?

1757


How to discuss the phase shift of transformer considering open delta?

1452


What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer?

1985


What is the reason behind current flow(20 A) in amain earth cable of an SMDB? Is cuurent flow(45A etc) through a neutral cable acceptable?

1963


According to conduit size which size wiring & how many wires can we provide wires in conduit & how can we select conduit size accordingly?

1879


what is 400kv doble circuit quadpole tower?

1929


Draw the single line diagram of the power station?

1071


what is feeder bay?

1575


Safety of on line ups

1921


why the projects getting loss?

1918


How to work meggar?

1811