How would i calibrate a new commissioned flow transmitter???
Answer Posted / satyendra bhai patel
dear friend,
just check orifice data sheet where u will find out the min
and max dp within lp & hp legs of tx.
as per given data set lrv and urv of tx from HART.
as per LRV & URV set 4-20 ma out put of tx.
thanks.
for any help contact me on 9005091827
| Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
Positioner usage.
Please send me the sample question of Instrumentation of hpcl/iocl exam. my mail id hihi_kiholo@rediffmail.com
what is compensation? temprature & pressure
what deference between panel earth and systemearth
In control valve proximity inductive sensor is taken as digital feedback for full open and full close.Normally its volts 24v when the sensor acts the feed back voltage 14v so that our relay not indicating in plc panel . kindly give the solution.
what can of fault ofently come in vibration mesurement?
Explain the working of an electronic level troll.
How an rtd work, and what volts/current goes to a rtd to measure the resistance?
How do bending tubing provide better measurement than using tubing fittings such as elbows?
(1) In turbine, what does term CDP, NI, NH, HSSOC, means. (2) What is the purpose of LO overhead tank in turbines.(3) An equipment is certified for EEX, IA, IIC,T6, what do you under stand by this.(4) what is SURGE, and how it is prevented, what is the purpose of bypass valve across AS valve.(5) Give 2 application of quartz crystal used for process parameter measurement.(6) what is meant by cold float of compressor shaft. (7) state four different types of flow measurement. For gas flow measurement mmscfd is the common unit. Expand the unit and specify significance of word S in the unit.(8) what is meant by Gap voltage, in vibration measurement. Normally how much Gap voltage is set and state the reason.(9) what will the new flow factor if D/P transmitter is Re-Ranged from 25” wc to 50” wc.(10) what is the usage of QDV & Volume booster.
Exothermic reaction./ endothermic reaction
any body please send me the old question papers of ongc test.
the 3 most common transmitter protocol being in refinery or qatar gas and aramco.
how does we calibrate a square root flow transmitter ,give an example and explain it step by step like range calculation , calibration hook up series connection , zero check , and how to apply pressure , and if not geting proportional output then what should we do ?
Why are the uses 24vdc in industries