Answer Posted / vivek pandian
FEED BACK
FEED FORWARD
CASCADE
SPLIT RANGE
DUPLEX
RATIO
| Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
What is wet leg condition and why is it used?
TEMPERATURE VARIATION FOR FREQUENTLY.
how to change measuring units from mmwc to cubm/h in rosemount air flow transmitter with hart communicator fluke 744
how do calibrate the valves.. with clear manual
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
What care will you take in the installation of control valves,SCADA,DCS and FOC in Oil and Gas Project?
I m appointed as an automation trainee engineer in small firm in that I am only the one , my company give me a project on s7-200 as i m beginner I don't know how to program so please send me the helpful site so that I complete my project before deadline....please help me out in this critical situation.
Programmable Logic control.
what is the field bus calble ? what are diffrences in orang colur cable and black coular calble ?
I will attend an interview with GasGas company for a position of Instrument Technician ( Offshore )in next month can anyone tell me what questions they will ask. Thanks in advance.
How to calibrate level transmitter with use of HART?
what is the difference between profibus and controlnet networking.
what is droop in governer ,type of droop ,how it work
please send data bank of quetions answers on analytical instrumentation.
what is the reset offset and control system in instrumentation