Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

In DM plant, If pH in anion outlet is 7.2 and Mixed bed pH is
6.2, wat could be the reason.

Answer Posted / raj kumar

mixd bed has the mixture of resin as strong base anion and
strong acid cation. so due to presence of acid cation ph is
reduced

Is This Answer Correct ?    61 Yes 22 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

hi can anyone tell me some technical questions asked in iocl

2247


Dear sir/madam I am in final year BE chemical engineering.Which companies i can apply .Please guide me.It is very helpful for me

2243


List the advantages and disadvantages of a pfr?

1076


i am appearing in railway section engg. exam of chemical eng. therefore i want previous papers and study material of chemical eng.

1915


MY generator water cooler inlet line height - 11 mtr inlet water line height - 7 mtr water come into the line from overhead tank, O/H tank height - 20 mtr the first tapping in the inlet line is 2" line which down to 4 mtr level plateform., second tapping in inlet water line goes to a pump 6" line installed at 4 mtr level plateform, pump capacity 200m3/hr, head- 30 mtr, hp-40. the outlet of pump of 6" water line connected to a header of 6 mtr long of 6" line, on this header the six tapping are connected, 4 nos. 3" line goes to 11 mtr height water cooler the pressure of the line is 0.15 to 0.25 kg/cm2, 2" and 4" pipe line connected to a cooler at 4 mtrlevel plateform. my question is, at 11 mtr height level the quantity of water and flow is not sufficient for my cooler, the temp. of cooler is rises much more. you are requested to suggest the modification of pipe line/ pump for take more water flow and pressure (desired pressure is 1 kg/cm2)

2378


Where barrel pump use?

1854


Explain what is the best way to configure a bypass line in slurry services?

970


What is maximum recommend pipe velocity for dry and wet gases?

1092


When should one be concerned with the tube wall temperature on the cooling waterside of a shell and tube exchanger?

1010


Explain the some guidelines for sizing a psv for a fire scenario on a vessel in a refinery service?

1092


What are the methods involved to test helium leak testing in a vacuum system?

1125


What's -74C, dew point is better the -70C dew point In draying unit .

2013


Explain can large temperature differences in vaporizers cause operational problems?

1042


What are the Major Utility Systems in a Pharma Plant? How are they interrelated?

1585


What are the factors involved in designing kettle type reboiler?