how to calibrate absolute pressure transmitter

Answer Posted / hitendra

procedure of absolute pressure transmitter:-

power supply:- I/P 24v dc to transmitter

multimitter connect with transmitter in series position
now when transmitter in atmospheric,transmitter o/p is 20ma
when applied 0.8to0.9kg transmitter o/p is 4ma

Is This Answer Correct ?    6 Yes 13 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how do u calibrate the vacuum transmitter if it shows more reading

1585


what is the PC interface and software for connection to ABB logic module “ LM011-CE18RAC “ ( for Programming ) ??

3433


send me model hpcl questions pleas..........my mail id mohideen.dharvesh@gmail.com

1743


why using negative supply for bentley nevada vibration system ?

1705


how will you check torque value during Factory acceptance Test for control valve/ESD ON/OFF VALE how will you confirm this torque value is being correct, Which document will you be refer.

2013






Senior engineer's please help me, what is Loop Checking and Loop test? and write difference also? soon urgent

1606


Specify for Cables - Flame Retardant and Fire Resistant?

1629


what is installation and commissioning of (fat & sat) of power plant dcs ? this question keeps in desirable conditions of one company .

4400


the 3 most common transmitter protocol being in refinery or qatar gas and aramco.

2482


how to check earthing,what is minum ohms for proper earthing

1512


What is standard of DCS panel design?and what is step of DCS panel design?wiring and type of connector(screw or DB connector)

1714


what is interface level measurement.who can calibrate interface level measurement transmitter online

1983


A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.

1686


What do you know about gail?

2046


in natural gas indirect water bath heater,how to prevent the problem of backfire from firetube during ignition...becoz of this backfire performance of wbh is going low.

2291