As you are fresher in Instrumentation & control
engineer.Then why should I select you?
Answer Posted / n.karthik
Show up your personal skills like Quick learning and
odaptability to new environment and you should provide good
communication skills.
In all the reputed firms, Experienced and also freshers are
required. So With confidence you can approach the Employer.
| Is This Answer Correct ? | 21 Yes | 2 No |
Post New Answer View All Answers
i am preparing for BARC ,so plz mail me how to prepare for BARC. ALSO IF POSIBLE SOME RELATED QUESTIONS. MY MAIL ID IS khushi_4uall2003@yahoo.co.in
How to Calibrate Ultrasonic Level Transmitter in field
How vortex sensor used for steam flow measurment can be checked on line i.e without taking out from process line.
why micro controller 8051/52's clock frequency is internally divide by 12 ?? and why it is further divide by 32 in UART serial communication ??
How an rtd work, and what volts/current goes to a rtd to measure the resistance?
while am calibrating Drager polytron 2IR flame gas detector occured non zero status.how can i get zero status?
what is gas metering system? gas chromatograph? and gas compressors?
is there any digitel grevity meter availaible in the market by which we can measure specific gravity of a battery?
what is dc moter.
Actual using of tube bender to bend 2 opposite 90 deg at correct measurement center to center of tubing.
A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.
How to calibrate RC Feeder system in thermal power station?,If any instrument available to calibrate it,ple inform me. make:stock,
SOME OF YOUR QUESTIONS ARE NOT MAKING ANY SENSE SO TRY AND PUT IN A LITTLE BIT MORE EFFORT BEFORE YOU POST A QUESTION. WE WILL ONLY HELP THOSE WHO WE CAN SEE ARE TRYING TO HELP THEMSELVES.
what is interface level measurement.who can calibrate interface level measurement transmitter online
why we use cascade control and feed foreword control in 3 element control of boiler drum ?what is feed forward and cascade control system ?