Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is transformar load balancing ?

Answer Posted / monika khare

Billing program (for PUDs, cities, etc...) that will track transformers.
Part of that is a 'load balancing' report. The example of a 'load
balancing' report that I have gives actual usage (in KWH) of all the meters
connected to it, converted to KVA and the % it is of the maximum KVA rating
of the transformer. My question is - should I be concerned with the actual
usage or the potential usage? My guess is that if every meter reads the max
usage, it will overload 99% of their transformers. Is this typical in the
energy industry? Are the transformers usually balanced with the actual
usage or the potential usage?

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

briefly explain principle of resistance welding

1816


What are steps to be taken while designing of DYN11 distribution transformer to achieve magnetising balance?

3481


how to select the mpcbs and contactor for 3 phase 30 hp star delta motors.for plc control.and tell me the calaculation for future use.

1923


Why the dc voltage drop during starting of emergency lube oil pump? The Voltage drop from 135kv to 125 kv for one min. before re-establish to 135kv?

2254


what is the size of cable for 15kw motor and 85 meter cable length using with vfd

2304


How can we select suitable capacity generator for three phase load (inductive load) and how to take study analysis in 3 three phase load system ?

2093


I have made a 3 phase thyristor full bridge rectifier. But at the moment it is working only for the half bridge operation. Both the half bridges are on operation separately but when i put it into full bridge operation the oscilloscope output is zero. I rechecked that the pulses are correct for each thyristor. what could be the possible reason for this?

1884


how to carry out Magnetizing Current Test on Distribution transformer and what purpose we are doing this test. why transformer rating in always in KVA ? what ispositive, negative, zero sequence impedence? How ElCB tripping if Neutral touch with ground Why AC & DC capacitor are use in UPS ? why motor rating in KW? how to syncronize two dg sets

2126


sir my exam is on 19/6/2013 under electrical branch pls send me sample aptitude questions as well as sample technical questions for jindal steel and power company

2128


what is a reactive power? what is the relation with power factor?

2109


How to decide DO set rating of Transformer?

1603


how oti and wti connections are different from each other?

1996


What are motor generator sets and explain the different ways the motor generator set can be used ?

1105


The specific heats of the gas at constant pressure and constant volume are respectively 1.0 kJ/kg K and 0.72 kJ/kg K; the value of R for the gas is

1071


what is the constructional difference between a power transformer and potentian transformer?

1701