Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the difference b/w wet leg & dry leg level method

Answer Posted / rohan murkar

The difference is ,In wet leg level.a condensate pot is
attached to txr LP side.Thus pressure also acts because of
the condensation of process liquid on the LP side of txr.So
we have to consider that pressure while calibration.

Is This Answer Correct ?    0 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Draw a complete P&ID of a flow suction tank indicating all control & protection equipment. Indicate all its inlets and outlets. Explain the controls for this system

1483


how to convert cubic metre per hour to newton cubic metre per hour

1957


what is the difference between -24 : +24 & 0:24 and where it use?

2017


what is span value and zero ? and how set ?

1488


In turbine what does term CDP, NI, NH, HSSOC means.

2499


Calibration procedure for Electro magnetic Flow meter

4433


all types of liquid analyzer principle with drawing?

1883


What is zero elevation and zero suppression?

2104


How oil line flow measured?eplain about instruments used and working principle?

1986


How earthing can be checked????

2352


how to calculate range of level transmitter?

2254


I am having a Phoenix digital to modbus converter. The o/p of the same is connected to flow computer FB407. But the digital signals are updated only after one minute in the flow computer. what may be the cause of delay in communication? Flow computer is having a scanning period of less than 1 sec.

1833


Explain the mechanism behind the turbine meter.

1061


In my company plc based winders are operated. one day there was a data transmission failure alarm shown on pc. as per sir instruction we have reset master plc but winders were not triped and alarm gone. so what master plc do?

1799


can anyone can let me know in Eurotron Micro cal 2+ calibrator in milli amps source mode we are not able to get 20 milli amps output it only produces 1.52 milli amps out, but display shows increase in milli amps , and err6 displays, let me know how to remove the err 6.

2203