what is difference between 1/2"NPT & M20 x 1.5 cable gland?

Answer Posted / ramesh sobhani

There is no difference in constructional dimensions and the
acceptable diameters in both the case. the difference is
only for fixing to the equipment. If the equipment is
having Npt thread then we have to use NPT glands and if the
equipment having blank holes then have to use M20X1.5
glands with check Nuts. whereas npt glands are conical
thread and are fixed directly on equipment No check nut is
required BRACO

Is This Answer Correct ?    55 Yes 15 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How many interlocks at turbine? Plz explain briefly

1531


what is the procedure of O2 sensor(ABB) calibration?

1718


what is function of SCADA , and how is it work, explain with difination

1838


How to regulate the flow of Air in 4" line, with max flow of 330 nm3/hr and Pressure of 0.5 bar? please suggest the type of instrument required.

1088


What is offset in a control system.

7975






draw the block diagram of a level transmitter ?

1940


How can test or measure the probe and extension cable to identify if the problem at the probe or cable or at the driver it self? (pleast notify the measuring method)

2135


Senior engineer's please help me, what is Loop Checking and Loop test? and write difference also? soon urgent

1615


why direct mounted pressure transmitters is always installed with DBB ( double bleed block) valve in process line or top of the tanks ?

1592


What is feed factor and its Importance in cement industry? How we can solve feed factor?.

3098


What denotes the 5/8mm in the 3300XL 5/8mm proximitor probe?

991


How will you calibrate PID controller? explain with example.

1981


which type inter lock use in petrochemical refinery,and oil & gas?

2637


which type of zones used for boiler? & why ?

1434


How to calculate P,I&D value in PID controller ?

1630