two bolbs of 100w and 40w respectively connected in series
across a 230v supply.which bolb will glow bright and why?
Answer Posted / harish kumar
Dear Friends,
1. When bulb are connected in series "CURRENT" is same , While "VOLTAGE" will be "DIVIDED" Across Each Ckt According to the Position of the circuit connected (As in Increase order)
2. And Voltage Is directly proportional to Light. If voltage is high than it will glow brightly and if voltage is low it will dim.
3. Now Consider V = 230v,
R1 = 40w
r2 = 100w
So P = V^2/r therefor R1 = (230)^2/40 = 1322.5 ohm
R2 = (230)^2/100 =529 ohm
So According to the OHM's Law V = IR
Resistance Directly proportional to Voltage.
so Voltage Directly proportional to Light.
Hence 40 watt bulb will glow more Brightly rather than 100w.
| Is This Answer Correct ? | 54 Yes | 18 No |
Post New Answer View All Answers
working principles of cf lamp,incandescentlamp and f lamp?
is it possible to say motor horsepower number without seeing name plate(when name plate damaged)
How to select transmission line type (i.e. 11kv or 33kv) for new established industries
HELLO EVERYONE, I RECENTLY HAVE FOUND ONE PROBLEM, I WAS TAKING NO LOAD TRIAL OF AN HT MOTOR 920 MOTOR , 1440 RPM , 6.6 KV, WITH AUTO TRANSFORMER. AT 450 V, LOAD WAS 40 AMP AND SPEED WAS 250 RPM. BUT AS WE INCREASE VOLTAGE FROM 450 TO 480V, LOAD BECOME 41 AND SPEED REDUCED TO SOME RPM . SO WHICH PHENOMENON ACTED HERE FOR REDUCING SPEED.?? AND IS IT HAPPENING ALWAYS OR IT IS RARE? I ALSO HAVE FACED SUCH PROBLEM WITH FEW LT MOTOR ALSO.
Ceiling Fan and Storage type water heater. Discuss
is it possible to start a motor in felid connected to a remote mcc
What are the advantages of skewing of cage rotor conductors?
what is droop control?
What test must you do before powering up a circuit that you have been working on?
In which of the following case, the rotating magnetic field is reversed? A regenerative breaking B plugging C dynamic breaking D forward motoring
Give atleast 20 alternating current apparatus and devices.
After taking shutdown of 11kv feeder, if you see 5kv by phasing stick in the cable side, is it possible to close earth switch in cable.
How will polarity test of Dy5 Transformer ?
How to Preparation of online test
we have 3 single phase transformers. how will we generate 6 supply from 3 phase supply input