why PT Primary are the grounded?

Answer Posted / p.k patel

voltage is measerd from line to grond and another reason if any fault occur at primary it will flow through the ground and equipment will protected

Is This Answer Correct ?    2 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

at what basis/standard we have to arrive the current density of aluminium/ copper in busbar?

1655


What is the restart inhabit setting in ABB spam150c relay (Motor protection relay)

3035


Why the standard of ambient teperature mentioned as 40 degree celcius in machines.

1447


What is pd controller?

645




1643






How many lightning arrestors to be installed on 50MX60MX10M building and is there any formular for that?

1466


Why does increasing the magnetic flux in the main field of a d.c motor cause the armature current to reduce??

1513


dear sir, i completed diploma in electrical in 2005, how i can get electrical supervisor liance in mumbai

1539


What is shutdown of electrical sub station?

1936


For R-L or R-C ckt,time constant formula is L/R and RC respectively and its unit is in sec.Pls tell me the derivation

2677


Why wind turbines wheels rotate constantly

634


What range of speed can you get with the field control method of speed control of d.c. Shunt motor?

655


What is the power requirement of tamil nadu for one month?

1556


Dear sir my name Ankit i m Diploma holder present working in Welspun Corp ltd Anjar as Asst.engg (salary 14400/month ctc) i Would like to change my company also i have selected in ford India pvt ltd Sanand as trainee Tech with salary 12000/month so please suggest me for changing my job hope for *ve response

2414


1)what is the function of a frequency inverter? 2)If a few frequency inverter are connected onto a device network,what are the two setting that will ensure the frequency inverter work properly on the network. 3)whats is the name of the input sensor for weigher? 4)How to confirm that the load cellis faulty? 5)Describe briefly the steps to validate that the weigher is working properly? 6)Describe the procedure to validate the flowmeter accuracy? 7)Describe briefly the steps to validate that the tempreture sensor/transformer is working properly. 8)what is the adjustment that need to be done when you are calibrating the temperature transmitter ? 9)what are the safety measures to be taken before disconnecting motor for rewinding. 10)whats is the synchronous speed in rpm of typical 4pole 50hz motor? 11)whats is the formula for kw, ohm's law 12)if a 3phase motor is rated 3kw,415vac,what is it's rated ampere?

1369