In RTU Panel we are having several Analogue & Digital
Inputs /Outputs. We are recently facing some problems over
Analog inputs , which are not updating properly (But
Digital Input are updating normally) Can any one tell me
from where the problem is creating , we have checked PLC
CPU card, Analog Input card & we reconfigured ,But still
the issue is there.
Issue :
1. Sometimes Analog values are updating & sometimes not.
2. Analog values are not updating normally , showing some
wrong Values
3. Total dead (0 value)
Analog values are Level & flow measurement from the field
instruments.
(But in field the instruments are working normally &
Displaying the values normally in local display unit)
This problem we are facing in our Water Plant.
If any one experienced this same problem or having any
ideas related to our issue PLS send your valuable
Answers/Replies...
Answer Posted / guest
analog values are normally between the limits.... if we are
changing the inputs...depends on that the output is vary...but
it is there in between the limits
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
how does we calibrate a square root flow transmitter ,give an example and explain it step by step like range calculation , calibration hook up series connection , zero check , and how to apply pressure , and if not geting proportional output then what should we do ?
How can measure flow in oil line?which type of transmitter is generally used?
Explain Gas Turbine startup and shutdown sequences
Lux meter is the measuring device to measure the lux level of lighting fixture. in industrial sector two types of lighting fixture is being used as street lighting purpose 1. HPSV (Sodium) and 2. HPMV (Mercury). HPMV having white light which is an combination of red, blue and yellow colour, while HPSV haivng Yellow lighting. in HPSV red & blue colour will be absent. during measurement of the lux level of HPSV and HPMV fixture. 1. Lux meter can measure the actual lux level of both fixture? 2. or it will show false reading for HPSV fixture light as it has only yellow light present. please give me answer
What is three element drum level control system why its better than single element?
Explain types of valves?
How does a single acting, spring return ball valve actually work? Does it require continuous air supply?
What is sensitivity in vibration probes..?
Explain the mechanism behind the turbine meter.
I want to measure and control level in tank of size 10*5 filled with gasoline, so plz give me the solution with clear details. how to select transmitter and sensors.
how to tune siemens sipart electro pneumatic positioner..plz tel me..
what are the definitions of input, output, command & signal according to instruments controlled by PLC using DCS System?
when a magnet is heated?
why we use impulse line of flow transmitter at 45 deg. angle both side of orifice plate.
how to design orifice plate?what is the equation?