in small capacitor we use uf( micro farad) and in big
quantity we used kvar. i want to know that in 1 kva how
much will b uf(micru farad).
Answer Posted / srinivasa rao talasila
KVAR = square KV * 2PIfc/ 1000
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
Practical condition in 400KV Sub station:- Breaker(open) , isolator(open), Earthing (close) at both end e.g A & B. Now Open A Stn Earthing than Open B stn Earthing (Which have a 50MVA reactor) , AND suddenly show R,Y,B phase 704KV,573KV,118KV respectively. Que is without closing of breaker how it is possible.???? My Whats app No:07621840498 for Further Discussion. Pls experts suggest.
how to generator maintenance (A Check, B check,Etc)
I am about to write exam in RRB bangalore for the post of section engineer.please provide me with previous exam questions
List out the different frequency domain specifications?
Saving in copper achieved by converting a 2 winding transformer in to an auto transformer is determined by A voltage transformation ratio B load on secondary C quality of core material D size of transformer core
how unidirectional torque is produced in DC motor?
What fomula is used to calculate: 1. rated frequency withstand voltage, and 2. rated lightning impulse withstand voltage.
What is a surge supressor why its is used in synchronous generators
what is the responsibility of C license holder in industry?
How we select the vector group of 3phase power transformer?
how can I calculate charging current of cable/overhead conductor? what is roll of voltage in it ?
What is the general system requirement of alternator?
what happens when dc generator coupled with cycle shaft.also explain what happens when its loaded
1)what is the function of a frequency inverter? 2)If a few frequency inverter are connected onto a device network,what are the two setting that will ensure the frequency inverter work properly on the network. 3)whats is the name of the input sensor for weigher? 4)How to confirm that the load cellis faulty? 5)Describe briefly the steps to validate that the weigher is working properly? 6)Describe the procedure to validate the flowmeter accuracy? 7)Describe briefly the steps to validate that the tempreture sensor/transformer is working properly. 8)what is the adjustment that need to be done when you are calibrating the temperature transmitter ? 9)what are the safety measures to be taken before disconnecting motor for rewinding. 10)whats is the synchronous speed in rpm of typical 4pole 50hz motor? 11)whats is the formula for kw, ohm's law 12)if a 3phase motor is rated 3kw,415vac,what is it's rated ampere?
What is the equivalent circuit of a transformer and its vector diagram?