can anyone help me regarding bout Electrical designs and
calculations .. which text book should i follow as i am a
trainee engineer.Description of my work which is Electrical
designs like cable sizing, lighting, lightning, Gensets
sizing, motor sizing, transformer sizing, generator sizing,
circuit breakers, PDB MCC PCC SLDB MLDB panels, Single line
diagrams mainly, substation desings, cable routing and
layouts, reactive power compensations, power factor
improvement, voltage drop calculations, power generations,
power transmission, power distributions all
calculations.Please help me
Answer Posted / kishore
sir , the above answer is particularly for machines and
power systems and switchgear like that but i need building
services for electrical engineering.. that means it consists
of Electrical designs like cable sizing, lighting,
lightning, Gen sets sizing, motor sizing, transformer
sizing, generator sizing, circuit breakers, PDB MCC PCC SLDB
MLDB panels, Single line diagrams mainly, substation
desings, cable routing and layouts, reactive power
compensations, power factor improvement, voltage drop
calculations, power generations, power transmission, power
distributions, illumination lux calculation
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
What are the types of the glands and difference between single and double compression type of cable Glands.
Dear sir my name Ankit i m Diploma holder present working in Welspun Corp ltd Anjar as Asst.engg (salary 14400/month ctc) i Would like to change my company also i have selected in ford India pvt ltd Sanand as trainee Tech with salary 12000/month so please suggest me for changing my job hope for *ve response
How can two 3 phase transformers of same KVA and Voltage be connected in parallel?
what is the relative size of single and three phase?
Why we use circular(Stepped) cross section in transformer core?
What is the different types of cable & current capacity of cable
how to discharge 3 phase power factor correction capacitors
How out of step protection relay works?
Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.
sent to a site and asked to explain how you would like a twenty seven flour building should be supplied with lighting and sockets plus a water boiler.
Dear all, how we select the cable size according to current with or without including different correction factor , is there any direct method for sizing of cable...
What is turn ratio of a transformer?
Should power factor be low or high?
3ph motor running with unequal kw and different pf what are the reasons
How to select transmission line type (i.e. 11kv or 33kv) for new established industries