What is the minimum percentage of power that a powerplant
can support in ilanding mode ?
Answer Posted / k.prakashchandra
That depends on governor.We were able to run even at 1% of
full load.With digital governor it is very easy in
PCS(constant rpm) mode
Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
In a single how much maximum current and watts using
there is an alternator 480 k.w, 400v,50hz, 4-wire running on load having leakage alternator body earthed current 38 A. is it within acceptable limit? if yes then give reference if no then how to bring within specified limit
A 400 V, 50 Hz, Δ connected synchronous generator has a field reactance of 0.1 Ω and armature resistance of 0.015 Ω. At full load, the machine supplies 1200 A at 0.8 pf lagging. Under full-load conditions, the friction and windage losses are 40 KW and the core losses are 30 KW. What is the machine’s overall efficiency? Ignore any field circuit losses.
how we can calculate chiller required ampear?
The transmission does not have options: a)Partition noise b) Flicker noise c) resistance d) Short noise and reason
how we can do the insulation on secondary of ct explain and so that tan delta will within limit
how to electrically make connection to ferroli GN2N?
What is VCB? where it is installed at SP. What is SP?
This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.
why occ characteristics of generator is also called as magnatization characteristics ?
Why do we use copper cable for HT Supply and why not Aluminium?
we have consol make 3 phase servo stabilizer for cnc m/c. while installing the earth neutral voltage is 1.7 volts at stbilizer off condition and when stabilizer get on en voltage reaches 4.8 volts (new earthing is done and neutral is helthy condition all phase to neutral volts 440,442,441 v)why this happen.solution for cause.
How to set the relay,,??
what things to be considered when designing UPS
Can any one know what are the symbols at the down (below) the analog ammeter??? there are 4 symbols which are they ?????