can anyone help me regarding bout Electrical designs and
calculations .. which text book should i follow as i am a
trainee engineer.Description of my work which is Electrical
designs like cable sizing, lighting, lightning, Gensets
sizing, motor sizing, transformer sizing, generator sizing,
circuit breakers, PDB MCC PCC SLDB MLDB panels, Single line
diagrams mainly, substation desings, cable routing and
layouts, reactive power compensations, power factor
improvement, voltage drop calculations, power generations,
power transmission, power distributions all
calculations.Please help me
Answer Posted / shoaib9786
A few good text books for electrical machine designs are as
follows :
1. Electrical machine design by A.K.Sawhney
2. Design of Electrical machines by Mittle and Mittle
3. Switchgear and protection by S. Rao
4.Electrical Power by Uppal
You may find the above books helpful...
Hope that answers
Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
what is the formula for efficiency of francis turbine and generator for hydropower? what is best way to select francis turbine and generator?
HOW WORK HEAT PLATE EXCHANGER
How do i perform grounding of star point of Genset (400V) for making connection with step up transformer of DELTA-DELTA (400V to 20KV) ? while Genset itself has its own neutral and grounding bus bar inside genset breaker box whereas we have another neutral and grounding busbar in synchronizing panel next to genset at maximum distance of 6meter, would someone pls advice if we can only perform neutral grounding in synchronizing panel or should we ground neutral on both places inside genset breaker box and synchronizing panel.
On a 6 KVA UPS we have to provide a DC MCB for Battery bank of 16 nos (12 V 42 AH). What Shall be the current rating of DC MCB ?
explain working principle of earth leakage relay
What is meant by stator? What is meant by rotor?
kindly send me 11KV MV motor differential protection procedure by primary injection method.
If any HVDC line is going with positive & negative(the negative usually have return path of current with earthing electrode). Now the question is if this HVDC earthed electrode which is using as return path and earthed any nearby 400kv or 220kv AC substation equipments. which will be the impact of this on AC substation & its equipment, how severe may be this and what should be the minimum distance require between HVDC earthed electrode and AC substation equipments? It's really an high engineering level question...Dare to answer and increase your knowledge.
What are unstable systems?
At the starting of dc motor and syn.motor and induction motor high current flowing through the winding. Due to this the windings burnt out. To avoid this different types of starters are used. But incase of transformer what Will be used (At starting no emf is induced in the primary winding)?
Is neutral transformer can be called as control transformer?
can you plz send l&t aptitude questions if available its urgent plz plz plz
If there are two transformer having rating of 2.5mva, 6.6kv/440v(satr-star),and the load is 600kw then what is better to maintain less losses in transformer having both transformer in parellel or only single transformer connected to load? Please give calculated answer
What is error of a measurement?
what a function diesel generetaor turbo charger & turbo charger is more heated explain reason ?