Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

In E&I diagram what is the meaning of rectangular box and circular box

Answer Posted / nilesh

Normally there is a P&I( Process and Instrumentation)
diagram not E&I diagram.In P&ID circle symbole related to
field mounted instrument while Square box with circle
inside is related to function in DCS.There is number of
other symbole in each catagory.

Is This Answer Correct ?    9 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

if in a level tx height is given, how u calculate the ranges of the tx?

7687


which type of signal used in instrument?

9818


What materials are used in thermo wells?

1152


what do u mean by compensation n pid tunning?in pid tunning what you tunned?is it possible 2 tune p i d

5352


Reason for capillary type dp level transmitter fluctuation

1967


all questions related to instrument technician in any offshore oil and gas company.

21659


What are the error values can accepted in flow transmitter calibration?could u give any formula for this?

1893


what is the procedure for auto tune in masoneialn 12300 series displacer type transmitter?

1620


List three types Level Gauges with their working principles

2070


Turbidity analyzer working principle ?

1771


What is the difference bitween control net scaner and device net scaner

3577


A DP transmitter is used to measure the level of an open tank. The drain line of the tank is connected to a control valve, and is configured as, if the level of the tank is 90% the valve should get open 10%. And if the tank level is 10%, the valve should get open 90%. Draw wiring diagram and explain how to configure DP transmitter and control valve using HART communicator. If the span error at output is 1%, what will be the %opening of the control valve at 60% level of the tank?

1386


why would you like to join our company

1360


why we use cascade control and feed forward control in 3 element drum level control measurement of steam drum .what is cascade and feed forward control system ?give example .

2863


How to Calibrate Vortex Flow transmitter in field

1257