what is the value of current and voltage that our body can
resist ?
Answer Posted / vinoth
Human body can resist up to 30mA only...
| Is This Answer Correct ? | 6 Yes | 0 No |
Post New Answer View All Answers
Is it possible to protect 3phase overload and earth fault of the 3phase system using two CT's.
What is transister define the transister ammiter ,base, colector.
Could u pls tell me the NPCIL electrical engineering interview questions for Executive trainee, and also guide me how to face the interview.
types of central Air conditioner plant?
what is difference between earthingpits,earthing grid & earthing mess?
what is the circulate the diesel in DG in side pls tell parts name and picture with circulate the diesel
Hi guys! Plz help me to answer the following questions. 1. What are the types of transmission line energy losses? 2. Why are the VLF are used some types of services? 3. What frequencies are used for reliable beyond the horizon terrestrial communication without repeaters? 4. To permit selection of 1 out 16 equi-probable, what is the number of bitis required? 5. What is the most common modulation used for telegraphy? 6. What is the multiplexing is used to increase the capacity of the optic fiber? Thanks
what is the principle of operation of tungstun bulb ??
When will you multiply and devide with derating factors to the actual value while sizing the cable?
how to caculate cable size for diff types of loads? if anyone know the calculating procedure please tell me
what is the function of capacitor duty contactor in an capacitor panel???
A double circuit with dog conductor 66KV Transmission line from wind farm evacuation to feeding substation having capacity of 25MW for transmission. Can same transmission network be considered for further expansion of Power & how much in MW. If we need to expand next 10-15 MW more will there any augmentation is required in transmission network? Kindly reply asap.
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
What are the causes of having an rmu explode after installation? And how do u treat the bushings of an rmu?
What is time invariant system?