what is a switchgear. what is its work & where it is used?
Answer Posted / satya
switch Gear means its having some switching equipments
like cbs, relays,isolators.
by using all these equipments we can control the voltage or
current
OR
The assembly of apparatus where we can placed and by using
thus we can control the electrical characteristics
these are mainly used at any where like
substations,transmission etc
| Is This Answer Correct ? | 4 Yes | 4 No |
Post New Answer View All Answers
What is the difference between UPS & inverter ? which UPS is better and whos got the edge ? what is the difference between & inverter ? which UPS is better and whos got the edge 12 V , 24 V , 36 V etc what are the advantages of 12 V, 24 V , 36 V etc and what are the disadvantages of 12 V, 24 V, 36 V etc thanks
How will change the frequency in distribution side?
what is the internal working of star delta starter
Why we use ups battery and dsdb battery in thermal power plant
1. What is differential relay? How it operates? 2.How to calculate the Short Circuit Impedance in Transformer? 3.What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works? 4. While testing the 33KV Busbar by using Hipot kit, what should be the test voltage we have to apply? 5. What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer? 6. Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example? 7. Why restricted earth fault protection is needed? Why can’t differential Protection is sufficient? 8. What should be the minimum and maximum ohmic value for earthing? 9. Why DC Currents are not used in transformer? 10. What is the Frequency while we step up the voltage from 220V to 11KV? Is it possible? Explain it?
what is the working principle of energy saver control panel. please give the complete calculation & theory.
define as synchronous generator
how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.
which are the criterias needed to select the kind of neutral earthing(solid earthing,resistance earthing,etc.) at various voltage levels in electrical distribution?
what is the ckt diagram of a tubelight and is it the simplest ckt of electrical engineering and also the component?
can we synchronize star system generators with delta system transmission line ? and how ?
is IS says that neutral should be brought to switch box. and this one is a recomended practice
Tell me the reason of connecting domestic t/f primary in star or delta,and also secondary side.
IF % IMPEDANCE OF A TRANSFORMER IS INCREASED FROM 5.8% TO 8% HOW MUCH THE EFFICIENCY OF THE TRANSFORMER WILL COME DOWN?
how do u gauge the size of the cable ?for eg. consider a 300 sqmm L.T Cable.How do u determine the size of the cable seeing it pratically?