Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

acsr dog conductor specification

Answer Posted / k.prakashchandra

Dia=14.15 mm,No. of strands/dia in mm Al-6/4.72 steel -
6/4.57,current for 30' C temp rise 254 A and for 50' C 311A
and resistance at 20'C 0.28 ohm/KM

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

For a 6.6kV Motor it is recommended to do megger test with 500 V d.c and not more than 5kV d.c but the Hi voltage withstand test should be performed by 12kV AC. Why the dc voltage test should be limited but AC voltage withstand test could be with such a high voltage?

2312


what is the use of Auto re-closer?

2120


What are the types of feedback oscillators?

1270


A logic circuit that provides a HIGH output if one input or the other input, but not both, is HIGH, is a(n)?

1201


Is vtg is controlled by the resistor? if else how much?

2066


please suggest some good universities with low cost iam in totally full confusion so please help me my profile gre 283 and ielts 5.5

1586


Advantage of LT panel vs HT panel

2908


what is difference between earthingpits,earthing grid & earthing mess?

2485


there is an alternator 480 k.w, 400v,50hz, 4-wire running on load having leakage alternator body earthed current 38 A. is it within acceptable limit? if yes then give reference if no then how to bring within specified limit

1907


What is core CT & it's function?

2174


How many wall/floor flange will i use in bus duct system if we have in our design a 35th floor building.

1483


Is any AC drive(VFD) had a feature of DC injection braking? if available please mention the detail. i.e drive can supply braking torque when the motor in idle state.

2127


what is cascade speed control device?and how this device control the speed of motors?

2135


What is evaporator & condencer & compressor

2142


A parallel flow heat exchanger will perform better than a counter flow heat exchanger. State if the statement is true or false.

1234