The DCS stand for________________________. it is composed of
the following major components:
a:______________
b:______________
c:______________
d:______________
Answer Posted / khalil ahmad khan
DCS stands for :Distributed Control System".
DCS System consists minimum of the following components.
1. Field Control station (FCS): It consists of input/output
modules, CPU and communication bus.
2. Operator station: It is basically human interface
machine with monitor, the operator man can view the process
in the plant and check if any alarm is presents and he can
change any setting, print reports..etc.
3. Engineering station: It is used to configure all input &
output and drawing and any things required to be monitored
on Operator station monitor.
| Is This Answer Correct ? | 5 Yes | 0 No |
Post New Answer View All Answers
Explain the working of an electronic level troll.
When doing a liquid seal on a differential flow transmitter , most of the time the sealing liquid will be heavier then the process fluid. For wich application will the sealing liquid be lighter than the process fluid if transmitter is mounted below the process line.
I WANT SECURITY PAPER MILL, HOSHANGABAD TEST PAPER.KINDLY SEND TO MY MAIL ID
What is the difference between PLC and DDC?
dear sir we have insatlled positioner model no.sipart PS2 make Siemens at our control valves . now problem is if we want to increase the response of valve opening speedy /fast. what parameters do we change for positioner ? any idea. please guide us.
Describe the function of Accumulator into the Pump
what is orfics working in main steam line. is it increase pressure, velocity of steam flow and dicrease steam flow rate. or any other
what does the ratio 800-400-300-200/1-1-1-1-1 in the specification of current transformer indicates?
the output of the common trasmitter protocol in qatar gas are the following
How to calibrate RC Feeder system in thermal power station?,If any instrument available to calibrate it,ple inform me. make:stock,
HOW TO SOLVE PROBLEM WITH ENRAF LEVEL TRANSMITTER 854 ATG THAT PASSWARD DO NOT Exist INTO TRANSMITTER TO ADJUST LEVEL WITH PORTABLE PET 847, WRITTEN WRONG PASSWORD , I AM SURE THAT DEFAULT PASSWARD (W2=ENRAF2) IS THIS TRANSMITTER NEED TO REPLACE SOFTWARE AND HOW?
can u plz send me technical questions asked in SCHNEIDER ELECTRICAL technical paper?
Specify eight technical requirements that you would consider important, when deciding upon a particular control valve?
What is force balance principle?
Instrument QA/Qc what is the project quality plan?conduit inspection RFI. which documents attache with package?