hello, I need to know exactly what happen in the motor
while it is connected to the (star/delta) starter,
mechanical and electrical. Thaks for answering
Answer Posted / mujeeeb
ACCORDING TO MOMENT OF INERTIA ,THE MOTOR WHICH WAS AT
REST TAKES MORE CURRENT TO START IT TAKES ABOUT SIX TO
SEVEN TIMES THE NOARMAL SO IT DRAWS MORE CURRENT ON ACCOUNT
IT TAKES MORE AMOUNT OF REACTIVE POWER SO THERE WILL BE
MORE BURDEN ON LINE SUPPLYING THE VOLTAGE TO THE MOTOR.SO
WE GO FOR THE STATERS TO REDUCE THE STARTING CURRENT TAKEN
BY MOTOR,IN STAR DELTA STARTER THE STARTING CURRNT IS 1/3
TIMES OF THE CURRENT TAKEN IN DELTA CONNECTION AT
STARTING ,SO WE START THE MOTOR IN STAR AND AFTER SOME TIME
IT WILL AGAIN RUN IN THE DELTA.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
1. If 8.35%Z means the percentage impedance of 132kV-line from power company, we will like to confirm its base capacity?
How the annunciator works ? How to do its wiring
what is the necessary of using inductance property in transmission lines even through resistance is used to opposes the high current flows in that?????
how you taken aotitude test
anyone please send transformer parameter design formulas & details of tap changer ? plz i have interview this week its more helpful for me ?
In control room of our one plant there is a continuously the incoming power goes to PC is vary,means in stabilizer it continuously indicate from high input to low and low input to high. what is the reason and its solution.
Why delta star trformers are used for lighting loads?
what is the safety points of vaccum circuit breaker.
What is different between resistance grounding system and resistance earthing system?
What is the most essential condition for the voltage build up for a d.c. Shunt generator?
why we are using earth pit in sub stations.?
how to calculate percentage impedence at 75 deg C at normal tap
What is the IS standard for MCCB to be use (As per capacity of AMP)& for ACB also.
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
1- What is the Polarization Index number be good for 15KV 3c#500MCM electrical cable? 2- Can I use the IEEE Std 43-2000 to perfom the PI test? Thanks