HOW TO CALCULATE SINGLE PHASE AMPERES IN 3 PHASE TRANSFORMER?
GIVE AN EXAMPLE PLZZZ
Answer Posted / k.prakashchandra
I= VA/root3 x V line -is the formula for current in each
phase or it may be written as VA/3 X phase voltage also.
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
What is the voltage gain or transfer function of amplifier?
we are small scale industry in production of rice & rice bran. Pls let me know how to take contract demand for our industry.. (for information we have total 600.hp)
how to carry out Magnetizing Current Test on Distribution transformer and what purpose we are doing this test. why transformer rating in always in KVA ? what ispositive, negative, zero sequence impedence? How ElCB tripping if Neutral touch with ground Why AC & DC capacitor are use in UPS ? why motor rating in KW? how to syncronize two dg sets
Explain what is clipper and clamper circuits?
Please tell me in DETAIL about the following 3 types of fuses or recommend me a good power system protection book or a website link ? 1.Dropout Fuse 2.Striker Fuse 3.Empulsive fuse (not sure if its impulsive or explosion fuse , sorry)
Can anybody inform me about the pattern of ECIL GET( Graduate Engineers Trainee) interview for Electrical students? Will there be HR round as well? I thought of preparing for 2 to 3 subjects thoroughly. Will it be sufficient? Please share your thoughts.
what should be the no load current for 3 phase ac motors ranging from 5 kw to 1000kw?
give single line diagram of D.G distribution form alternator to main L.T panel?
why the neutral line is not giving shock to us if we touch it ?
What is the role of Dedicated earthing in UPS System?
A 50Hz,4-pole,3-phase,star-connected synchronous motor has a synchronous reactance of 12ohmsper phase and negligible armature resistances.the excitation is such as to give an open-circuit voltage of 13.2kilovolt.the motor is connected to 115kilovolt, 50hertz supplying. what maximum load can be the motor torque,line current and power factor?
what are the standard IR values should be of R-E, Y-E, B-E, R-Y, Y-B, B-R of VCB in closed condition and in open condition for 500KVA & 1000KVA transformers. and what is the acceptable range when tested by 5000V megger.
How to Calculate KA Rating of Main LT Panel
The advantages of Magnetic flux leakage technique over Ultrasonic technique for non distructive testing of material.
what is the diference between the 4pole & 6pole DC Motors & what is advantage 6pole over the 4pole ?