When the German company AEG built the first European generating facility, its engineers decided to fix the frequency at 50 Hz, because the number 60 didn’t fit the metric standard unit sequence (1,2,5). At that time, AEG had a virtual monopoly and their standard spread to the rest of the continent. In Britain, differing frequencies proliferated, and only after World War II the 50-cycle standard was established. A big mistake, however.
Not only is 50 Hz 20% less effective in generation, it is 10-15% less efficient in transmission, it requires up to 30% larger windings and magnetic core materials in transformer construction. Electric motors are much less efficient at the lower frequency, and must also be made more robust to handle the electrical losses and the extra heat generated.
Today, only a handful of countries (Peru, Ecuador, Guyana, the Philippines and South Korea) follow Tesla’s advice and use the 60 Hz frequency together with a voltage of 220-240 V.
Originally Europe was 110 V too, just like Japan and the US today. It has been deemed necessary to increase voltage to get more power with less losses and voltage drop from the same copper wire diameter. At the time the US also wanted to change but because of the cost involved to replace all electric appliances, they decided not to. At the time (50s-60s) the average US household already had a fridge, a washing-machine, etc., but not in Europe.
The end result is that now, the US seems not to have evolved from the 50s and 60s, and still copes with problems as light bulbs that burn out rather quickly when they are close to the transformer (too high a voltage), or just the other way round: not enough voltage at the end of the line (105 to 127 volt spread !)
| Is This Answer Correct ? | 6 Yes | 2 No |
Post New Answer View All Answers
What are the disadvantages of autotransformer?
Can we use 230VAC, 63A MCB for 120VAC, 63A supplied heaters load?
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?
How many types of protection relays are there based on the characteristic?
wat is d diffr btw shunt coil and trip coil in VCB?
What is the difference between Generator Differential Relay and Transformer Differential Relay?
what is the difference between the voltage of 5 volts capacitor and and 5volts battery?
how to calculate cooling requirement of datacentre from electrical load?
IF ANYONE HAVE ANY QUESTION ASK ME AT MY MAIL anmol.bhardwaj5@gmail.com
In a single how much maximum current and watts using
please send me previose rrb junior engineer qustion papers
hello!my name is sheikh iam preparing for indian engineering servieces,please send me the old question papers..to sheikhshaazforjobs@gmail.com
Explain how you intend to work under pressure to meet up with deadline target?
What would cause a 240v choke that should give 110v out on a 16w lamp to gradually increase to 160v?
what happens to the water pump if ground water level is slowly decreasing?our water pump is varying from no-load full-load due to this problem