Answer Posted / gnanprasad.korrapati
When the German company AEG built the first European generating facility, its engineers decided to fix the frequency at 50 Hz, because the number 60 didn’t fit the metric standard unit sequence (1,2,5). At that time, AEG had a virtual monopoly and their standard spread to the rest of the continent. In Britain, differing frequencies proliferated, and only after World War II the 50-cycle standard was established. A big mistake, however.
Not only is 50 Hz 20% less effective in generation, it is 10-15% less efficient in transmission, it requires up to 30% larger windings and magnetic core materials in transformer construction. Electric motors are much less efficient at the lower frequency, and must also be made more robust to handle the electrical losses and the extra heat generated.
Today, only a handful of countries (Peru, Ecuador, Guyana, the Philippines and South Korea) follow Tesla’s advice and use the 60 Hz frequency together with a voltage of 220-240 V.
Originally Europe was 110 V too, just like Japan and the US today. It has been deemed necessary to increase voltage to get more power with less losses and voltage drop from the same copper wire diameter. At the time the US also wanted to change but because of the cost involved to replace all electric appliances, they decided not to. At the time (50s-60s) the average US household already had a fridge, a washing-machine, etc., but not in Europe.
The end result is that now, the US seems not to have evolved from the 50s and 60s, and still copes with problems as light bulbs that burn out rather quickly when they are close to the transformer (too high a voltage), or just the other way round: not enough voltage at the end of the line (105 to 127 volt spread !)
| Is This Answer Correct ? | 6 Yes | 2 No |
Post New Answer View All Answers
Why in power plant projects we see DOL starting method used for motors upto 160 kW instead of star delta method
What is the lifetime of a Thyristor? Is there a recommended lifetime for thyristors after which they should be replaced?
how can we find thae value of capacitor for single phase motor. what is difference between starting capacitor and running capacitor.
how can motor both beasrings insulation resistance can be check?
Define step response?
what is the power rating of CPU, CRT type moniter, LCD type moniter,scanner Approx.
How would your past experience translate into success in this job?
how we control automatic generator i'e with to supply (main supply and local generator) when the main supply was break to supply the local supply automatically to begin supplying power.I now this control circuit is the combination of contactor time delay contactor switch and overload relay .but my question is how we combine those component thank you
Mention the disadvantages of low power factor?
Make a list observation on Transformer?
1.what is meaning of curve into a mcb. 2.what is basic reason changing of curve
How we can calculate the consumption in kwh of motor on basis of kw @100% load, @50% load & @ no load.
how does an encoder work???
why do we put a transformer on soak before loading it
Draw the line diagram of diffretial relay connected to transformer?