Why we use a shunt capacitor or synchronizing Motor To
Improve a Power factor pls reply me in this mail
dinesh_elect_eng@yahoo.com
Answer Posted / k.prakashchandra
The synchroscope consists of two phase stator. The windings
are at right angles to one another and they are connected to
incoming generator.To have a rotating field ,the current in
one winding is made to lead the current in another by 90'
using a capacitor, as in a single phase motor.The polarising
winding in rotor (pointer) is connected to running generator.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
What is pd controller?
What are the advantages of nichols chart?
sir iam from electrical and electronics branch ,can i appear for the hpcl offline requirtment? if yes please mail me on vikram_raju25@yahoo.co.in
Either It Possible a dc Motor to Run On Ac Drive [ Ex : ACS 800 , Yaskawa F7 ] If it is Possible How Pls Inform Me dinesh_elect_eng@yahoo.com
What is slope...? Explain slope 1 and slope 2...?
defination of lines
Explain the different methods used in the choice of rotor slots for reduction of harmonic torques in an induction motor.
what is die electric strnth of transformer ?
Why do power lines not short out when they fall into water?
Give idea about General Engineering. From which book i can study this topic. Pl. reply me via email. My email is ravi@bhelhwr.co.in, also give the name of book/website, from where i can prepare it.
Dear Mr B C pal...Can you plz. put some light on principle of operation of Z-Ct in conjunction to its use with 1Cx1000Sqmm HT Cables & Directional Ground Fault / Over Voltage Relays...Regd..Parag v K 9899115632
state the working of discharge lamp?
give some advantages and disadvantages of combiniing the session, presentation, and application layer in the osi model into one single application layer in the internet model
How capacitor improves pf
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.