how we can calculate the transformer size.
Answer Posted / kamlesh rudra
Requierd ment Of Load.
Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
Please clarify, 1. Is it required to lay two runs of GI wire along with Armoured LT cable if it is laid between one big mains (63Amps TPN SDF) to small main (32A TPN SDF) with proper glanding termination? 2. If the armoured cable with proper glanding is laid from DB to CNC machine, is it required to run two runs of body earthing to the Machine from DB? 3.If the armoured cable with proper glanding is laid from Substation to Hangar, distance is approx. 100 mtrs, is it required to do earthing at shop area though the primary termination at substation is earthed through gland.
how can maintain the power factor and why and this is how do work tell us
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
What is Faraday's law
how can i determine the gear ratio for a rack and pinion system if an electronic gate operated by an electric motor is to travel a distance of 5meters in 15 seconds.
Why insulation level follows this order? transformer < bus bar < circuit breaker & Isolator < transmission line.
In case of generator when we consume more power produces by it why load on generator increase and starts sound more. and how it is adjusted..
PLS SEND THE RRB CHENNAI MODEL QUESTION PAPER my email id is ganesan98655@rediffmail.com
WHY THE COLOR OF OUTDOOR TRANSFORMER IS BLUE ONLY???
What are the advantages of a three-phase system over a single-phase system?
How we calculate DC inducation moter Amp? Sir pls give me formula......
Why L.T.Cable voltage rating is 1.1kV,where as system voltage is 0.415kV?
Do u know any one? how to find out in motor rated amps? formula?
i m in need of current rating chart of heavy duty pvc/xlpe, cu/al cables. can somebody provide me? if yes, plz send me at ashish_patel111@yahoo.com
What do you mean by lighting transformer?