Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is meant by Ac & DC drives where its useful ? how its
functioning ?

Answer Posted / n rajesh

AC and DC drives are used for smooth speed control
purpose.Now a days A.C drives are prefered due to low
maint.

Is This Answer Correct ?    9 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How shall i select the value of capacitor or inductor in a system?

1953


what is the saturation point of crgo lamination.

2301


how flow current in 220 kv line to line

2042


how we control automatic generator i'e with to supply (main supply and local generator) when the main supply was break to supply the local supply automatically to begin supplying power.I now this control circuit is the combination of contactor time delay contactor switch and overload relay .but my question is how we combine those component thank you

2046


I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

1941


how we do Vector group ,magnetic balance and tap changer test in Transformer?

2520


what work will do diffrential realay DG set

2967


What is the lockout relay

1579


how is control wiring coding is done in a CRP panel ?

2081


what is the meaning of WYE and DELTA in Electric meter?

3874


I'm generating a pulse of 3V with frequency 80Hz (12.5ms time period) and pulse duration 0.125ms and feeding it to a transformer since i want the pulse to get amplified around 60V. At the output amplification s happening but the pulse is changed to a spike, can you tell me what could be the reason? (an ordinary transformer 220V-12V stepdown transformer is reverse connected ie. now it is 12V-220V stepup and voltage amplification happens)

1954


how the speed of the gets motor regulated. does it draw the same current on the all speed level.

2031


how will we calculate the copper wire load..

1989


how electrical earthing maintenance done in industry?

1691


Testing report of Earthing of 3.15 MVa PTR.

2644