WHAT IS THE FULL FORM OF ONAN ( TYPE OF COLLING IN
TRANSFORMER)
Answer Posted / anjani
oil natural air natural
Is This Answer Correct ? | 9 Yes | 0 No |
Post New Answer View All Answers
Diagram on interconnectivity of 11kv transformer with RMU (i.e, one incoming and two outgoing or two incoming and one outgoing)
what are the different sizes of U.G. cable & where these cabl;es are used according to voltage ..
what are the principles of a booster converter?
In motors how many types of cooling systems were used?
How you calculating the 30 Hp 3 phase AC motor of power what size of cable is used for this motor?
What is 100% protection of generator? Why 100% is not used but 95% is generally used?
1)what is the function of a frequency inverter? 2)If a few frequency inverter are connected onto a device network,what are the two setting that will ensure the frequency inverter work properly on the network. 3)whats is the name of the input sensor for weigher? 4)How to confirm that the load cellis faulty? 5)Describe briefly the steps to validate that the weigher is working properly? 6)Describe the procedure to validate the flowmeter accuracy? 7)Describe briefly the steps to validate that the tempreture sensor/transformer is working properly. 8)what is the adjustment that need to be done when you are calibrating the temperature transmitter ? 9)what are the safety measures to be taken before disconnecting motor for rewinding. 10)whats is the synchronous speed in rpm of typical 4pole 50hz motor? 11)whats is the formula for kw, ohm's law 12)if a 3phase motor is rated 3kw,415vac,what is it's rated ampere?
Define cut-off rate?
sir, iam a electrical engg graduate and i want to go in automation sector and for this i have decided to do industrial training for this,plz suggest me some good institute for the same in delhi,ncr. my degree percentage is 58%, can i get job after doing training, plz help....
xpression 'document.FrmQF.myemail' [
In hydel power plants, L.A's, S.C's are placed inside the control panel boards. what is the purpose? [already the total body was earthed to ground.]
Practical condition in 400KV Sub station:- Breaker(open) , isolator(open), Earthing (close) at both end e.g A & B. Now Open A Stn Earthing than Open B stn Earthing (Which have a 50MVA reactor) , AND suddenly show R,Y,B phase 704KV,573KV,118KV respectively. Que is without closing of breaker how it is possible.???? My Whats app No:07621840498 for Further Discussion. Pls experts suggest.
direction of tarbine& genrator
Explain what is rated speed?
why tertiary winding is used in transformer with diagram?