DEAR SIR,
HOW TO CALCULATE WELDING TRANSFORMER CAPACITY IN KW OR KVA
(POWER). TWO WELDING TRANSFORMER USED WHAT TYPE OF DG SET
CAPACITY LIKE ( 45 KVA OR 62.5 KVA), PLEASE TELL THE WELDING
TRANSFORMER RATEINGS. I AM REFINARY (TANKS WELDING)
THANKING YOU
Answer Posted / k.prakashchandra
Name plate rating is the maximum capacity i.e. rating at the
highest secondary voltage.At this, you have to follow the
duty cycle of 30 seconds use and 30 seconds rest.Half of
this rating is the continuous maximum capacity.
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
What is meant by Im=30mA@Vk/2. How to know the kee point voltage for CT design
Write the force balance equation of ideal dashpot element.
why dimmerstate always connected in star connection? what will happen if it connected in delta?
What are the causes of having an rmu explode after installation? And how do u treat the bushings of an rmu?
describe the Operation of induction generators from bus bars
A Question Like A Wire Is Wound Whose Resistance Is Some 132. 44647 Ohms. If A Voltage Of 30 mv, 296 Ma Current Is Applied To It What Is The Resistance.
What is the previous name of Cox's Bazar
Explain how you intend to work under pressure to meet up with deadline target?
EXPLAIN THE WORKING OF SERIES REACTOR IN HT CAPACITOR BANKS (FOR VOLTAGES & CURRENTS)
What is the limitation of kirchoffs law?
Why does an induction generator is preffered as compared to synchronous generator in especially a wind energy power production project?
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
HOW TO CALCULATE THE HEAT AND LOAD OF LT-SUBSTATION WHICH CONTAINS 2*1MVA TRANSFORMERS,LT-SWITCH BOARD,MLDB,ACB,BUSBAR,ETC,......?
What are the different types of hydro schemes?
Why we are using Isolation Power Transformer inplace of commercial power transformer? What's the difference between them?