Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the working principle of ABB gas analyser of kiln
in cement industries

Answer Posted / bilal

O2 Analyzers Principle:- the basic principle of that
analyzer is Paramagnetic system its installed the coil and
when we need to measure the gas we generate the e.m.f Oxygen
elements drooped there then we measured the value.

Is This Answer Correct ?    17 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the difference between profibus and controlnet networking.

3280


If a control valve is hunting means means if we are giving 50% to the cv, the cv will open at 51% then slowly slwoly it will reaches 49% , so what to do for solve this problem. The cv is double acting and mounted for anti surge operation, it having 4 nos. volume booster, one sov, one positioner, etc..?

2147


what do u mean by compensation n pid tunning?in pid tunning what you tunned?is it possible 2 tune p i d

5508


Instrumentation symbols interpration, P& ID, Logic diagram analysis, Electrical drawing analysis.

2018


in which principle pressure tx,level tx ,flow tx,temp tx ,control valve works?

3240


Positioner usage.

1980


why I need valve guard and whats different between guard and positioner ??

1429


what is performance test.need defination

1766


Why does a pressure gauge installed on reactor, doesn't have any vent line below to release the pressure? Is it any kind of designing mistake or it actually does not require any vent line? And if it does not require any vent line below it then how we are gonna release the pressure built inside the pressure gauge?

2217


How would you choose differential range?

1225


Describe the typical instrumentation used in monitoring the performance of a shell and tube heat exchanger.

2124


centrifugal compressor interlock? Tell me the parameter at which compressor will trip

3236


what is use of communication wire in multipare cable(oil and gas field), why this communication wire not used in single pair cable?

2215


what is easiest way to read STL language in PLC?

3184


please send the drdo exam paper

2432