how the length effects the ampacity of the cable? if a cable
is carrying a current of 100A for 50m length then what will
the effect on current if we double the length?
Answer Posted / 98794
CURRENT WILL REDUCE
Is This Answer Correct ? | 1 Yes | 1 No |
Post New Answer View All Answers
What is formula calculation size cable wire ?
What is the phase relationship between the primary and secondary voltages of a transformer?
While converting delta into star or star into delta ,the three values of resistances remains unchanged .Find out the value?Let In star R1=x;r2=x;R3=x On converting into delta,R12=x;R23=x;R31=x Find the value of x
what r the checklist while installing 500 kva transformer
what are your career plans upon completion of the programme and the relevance of recity generation to your professional development?
How time response of the system is divided?
What is cross over distortion? How it can be eliminated?
can anyone explain 11kV 3core cable megger,hi pot test procedure with connection details?
How can I calculate ISF of current transformer?
Please explain me about Relay curves and their sources to read ?
Brushes are placed at magnetically neutral axis,when brushes reach that point,the armature conductor gets shorted,but it can be seen that the dc supply is also shorted,wont that get damage? help me plz
State the other types of Air Conditioners?
what is draiv work
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
Actuality I have at home electrical panel with 220v 50hz, and I want to converter from there to 110v 60hz, to wiring on the half of my house. Also I like to keep another half of my house with the original 220v 50hz. What is the best and safety way to do?