Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the right cable size for 100 hp mpter.

Answer Posted / nagarajan a

suitable cable for 100hp motor aluminium 95 sqmm. cupper 70
sqmm... cable size is depends upon the motor full load
current rating...

Is This Answer Correct ?    13 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2197


what is meant by impulse voltage?

2069


define displacement & magnitude ?

1888


How to measure power in 2 or 4 or n phase circuit? Please give me a formula.

1958


how we do Vector group ,magnetic balance and tap changer test in Transformer?

2517


Whats the minimum value for I.R. that can be allowed for HT & LT alternators for operation?

4148


why we used dc supply for field in dg set

2432


use of choke in APFC panels

5920


what is meant by skew width in machines?

2269


if in 3-phase system voltage=440V,frequency=60Hz, current=400A. then if it is single phase then current=? and if it is single phasing then current=?

2610


What is Scheme Test of High Voltage Switchgear. Which tests it includes.

2468


Differentiate between digital phase converter and ordinary phase converter.

1282


Why slip ring ind. motor power consumption is low compare to induction motor .same 90 kw motor used same load output

1895


The specific heats of the gas at constant pressure and constant volume are respectively 1.0 kJ/kg K and 0.72 kJ/kg K; the value of R for the gas is

1188


The sodium vapor lamp is not glows when it is connected a distance of 5 meters above from gearbox, why ?

3721