Can any horizontally mounted motor be used as vertical?
Answer Posted / vishal ingle
I AGREE WITH MR. RAMESH KUMAR.
ELECTRICALLY THERE IS NO PROBLEM
HOWEVER MECHANICAL ASPECTS TO BE CONSIDERED
SUCH AS TYPE OF LOAD, BEARING SPECIFICATIONS,
TYPE & STRENGTH OF FOUNDATIONS.
| Is This Answer Correct ? | 3 Yes | 2 No |
Post New Answer View All Answers
What types of question are done for diploma students in aptitude test
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
Why computer humming sound occurred in ht transmission line?
(1)The demand for electricity , the amount of renewable generation available, the amount of fossil fuel generation available and the cost of the fossil fuel generation are shown in table below period(hrs) demand(MW) renewable (MW) fossil- fuel(MW) cost of fossil fuel(MW) 00.00 - 01.00 2000 1800 2000 30 01.00 - 02.00 2300 2500 2000 30 02.00 - 03.00 2500 2700 2100 45 03.00 - 04.00 2900 3100 2100 50 04.00 - 05.00 2700 2600 2500 45 05.00 - 06.00 2400 2000 2700 50 06.00 - 07.00 2200 1800 2000 36 07.00 - 08.00 2100 1600 2000 36 Assuming that the renewable generation incurs zero cost, determine an optimal generation schedule(specifying the amount of renewable generation and fossil fuel generation used in each period, the cost for each period and the overall cost for 8 hours.)
write encoder 17 pins details? pin a;b+, pin b;w+,..pin s & t. what is the meaning of b+, w+? explain;
Explain The Application Of Storage Batteries?
What are the effects of electrical faults?
Can any body tell me the different types of LT cables & their application.
Dear Respected sir how to test ABB REX521 protection relay by relay tester.
explain single phase series motor
Define corner frequency?
A 500 V shunt motor runs at its normal speed of 250rpm when the armature current is 200A. The resistance of the armature is 0.12 Ω. Calculate the speed when a resistance is inserted in the field reducing the shunt field to 80% of normal value and the armature current is 100A.
I have doubt that the supply HZ (very low or high than rated ) may affect the power factor. is it true. ?
Hi Friend I am used multimeter to measure the voltage between R Phase(SS1) to R Phase(SS2). In SS1 is connected with UPS loads. But I am getting voltage between these 2 R Phases. Please give some idea friend
why use phase displacement in transformer.and effect of phase displacement on transformer