Answer Posted / rajkumar
No, the size of the bus duct will not accomodate the CBCT.
CBCT mostly used for outgoing motors feeders..
| Is This Answer Correct ? | 2 Yes | 1 No |
Post New Answer View All Answers
What is Servo Ventilated Motor?
Why do not we prefer non conventional sources of energy to conventional sources?
What is true sine wave or pure sine wave inverter?? Is it sine wave or step wave?? If it is step wave, waves with how much step is considered as pure sine wave? Is it possible to produce pure sinewave using power electronics?
why we use four type of phase angle difference between pimary & secondry winding of a transformer & where we use them?
we all know voltage is a force(emf), and the force always devides if 2 or more than2 loads are there but why does the voltage remains same is parallel, it must devide na ???
what happens if dc supply is given and the remedies for it.
how to interlock 3 nos MCCBs using under voltage coil. please provide me circuit diagram?
Briefly describe your ideal job?
Why 30kw 40 hp 4 pole 3ph induction motor over heated?any steps on reduction in heat?
If I have Energy Meter Ratio as 100:5 & Also I have CT Ratio as 50:5 then what will be my multiplying Factor(M.F.)
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
what is the use of surge suppresser in 33 KV incoming panel. where it must be installed,inseries with incoming cable surge suppresser must be at incoming of the breaker are outgoing of the breaker
How to calculate the size of earth cable to earth the neutral of UPS ?
Whats the minimum value for I.R. that can be allowed for HT & LT alternators for operation?
can we use ZNyn11 transformer instead of Dyn11 transformer in distribution for effectively eliminating harmonics from the industrial loads.