Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

WHAT IS OLTC OF TRANSFORMER? WHERE IS ITS USED EITHER ON
PRIMARY OR SECONDARY SIDE OF TRANSFORMER?

Answer Posted / kedar

OLTC means On Load tap changer of transformer used for reliability of power supply.
OLTC can be on either side of transformer.It depends whether the transformer is step up or step down. For Step Up transformer it will be on Secondary side(H.T) while for Step down it will be on Primary side(H.T) of the transfomer.

Is This Answer Correct ?    5 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What are the various kind of cables used for transmission?

1146


what is the formula for calculating the phase clerance between two phases and phase to earth how to calculate the cable for a motor

2100


Why do we require transformer with less specific weight if supply frequency is increased?

1633


if any body have question paper of railway (section engineering),then plz send me .i will thank of him/her.

2036


What is servo motor and what are different types of servo motor

2465


why T/F winding temp measurement cts are odd secondary current ie,109A/1.2A/1.4A?

1923


Explain forward resistance, static resistance and dynamic resistance of a pn junction diode.

1271


Explain difference between stand by earth fault and residual earth fault protection?

2062


why ct ,cvt should be stored in a vertical position?

2692


I WANT TO know WHICH WAY IS BETTER FOR CONNECTION BETWEEN POWER TRANSFORMER AND MAIN DISTRIBUTION PANEL. 1-IS BETTER WE USE CABLE? 2-IS BETTER WE USE BUS DUCT? my transformer rate power is 2500KVA

3309


What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side

1514


Where can I get CPWD electrical specifications & Shedule of rates? Please help me

2304


in the directional overcurrent and earthfault protection,normally we are setting the angle 45 deg lead for phase fault overcurrent and -45 deg lead for earthfault fro forward direction.but both the fault are operating on the same angle region only.why?how the relay will response?

1884


i have 90kw motor.so i choose connect cable .please what is parameter checked so please give to formula

2256


HOW MUCH CURRENT DOES SYNCHRONOUS MOTOR TAKES AT SYNCHRONOUS SPEED IN NO LOAD CONDITION ?

1908