What do you mean by 4.44 in this transformer equetion
E=4.44 nfqm
Answer Posted / usman
this is an empirical relation. u cann`t justify this . if u want to know where it came from u should see its derivation
| Is This Answer Correct ? | 1 Yes | 5 No |
Post New Answer View All Answers
hey guys help me out.....what are the industrial uses/functions of nozzles in industries
Meter p.t. ratio= 3×230/400 , c.t.ratio = 3×1 (2) A what is m.f.
My question is whether bellow formula is correct to find bus size for 46kA for 0.5 second & what is RT in bellow formula. formula to calculate the size of busbar to withstand the thermal stresses due to currents with duration of 0.2 sec to 5 sec. Sp = RT( I x I x t) / K Where Sp – is the cross sectional area of bus bar in millimeters. I - is the value of AC fault current. t - is the operating time of disconnecting device in seconds. K – is the factor depending on the material of the conductor, insulation and initial and final temperature. Value of ‘k’ for copper is 143.
1)we have 1000 cfm Blower,Dia-1Mtr,Velocity of air 94 m/s 2)We have Natural Air velocity 94m/s 3If i Put Wind Mill in natural air ,speed is 94m/s Then it will generate Assume 100kw 4)If i put same wind mill across the Blower,air speed is same 94m/s now the Question is Will it generate 100 kw?
What must be the minimum distance maintained between 2 Generators as per International standards?
design a LV scheme for a 15 storied building?
it is in our knowledge tht right plug of supply of residential suppy system is phase n other is neutral...howevr the battery charger of mobile works in both ways...i mean it is not restricted in only one direction.ny of the holder of charger can hav phase .so y is it not lik tht phase of supply must b connected 2 phase of charger...?
How to calculate approximate load loss of a distribution transformer by knowing %ge imp of transformer?
How to design the earth grid for lightning protection in an industry
State norton’s theorem?
How i can calculate current of cable according to ares?
What is the unit audit? if our Max demand is something and we found much more unit then how to improve our max demand?
IN MY SYSTEM THERE IS ONLY OVER CURRENT EARTH FAULT RELAY IS AVAILABLE. FOR THE UNBALANCE SENSING IS THERE ANY RELAY IS AVAILABLE? THE SAME CTs WHICH ARE USED FOR THE OVER CURRENT EARTH FAULT RELAY CAN USE FOR UNBALANCE ALSO?
What are the advantages of the three-phase motor over single phase motor?
How to Prepare preventive maintenance shedule of machine tool.