how to calculate the current carrying capacity of a
conductor. How it is related to diameter of cable or
conductor
Answer Posted / c.rajesh
generally current carrying is depends on resistance of
conducting elements but we now pure conductors are not exists
so internal resistance is considered now calculation is made
as resistance directly proportional to area of conducting
element R=l*a/s
here l=length of conductor
a = area
s = specific conductance
| Is This Answer Correct ? | 2 Yes | 15 No |
Post New Answer View All Answers
why electron produce magnetic field when it is in motion?
What is transister define the transister ammiter ,base, colector.
features of hbc fuses
dg earth connect only in the amf panel or not why
What is A check, B check, C Check & D check for a diesel Generat
how can you calculate fault level ?
What is the difference between single core 2 wire and single core 3 wire system? Which application we are using this? and for What purpose we are using this?
I have c license but I don't know eligibility of Max Kilo Volts under the electrical licensing board.
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
An 8 pole, 50 Hz, 3-phase IM is loaded to a poing where pull out torque will occur. The rotor resistance per phase is 0.3 ohm and motor stalls at 650 rpm. The slip when motor stalls is A 1 B 0 C 13.33% D 10.33%
WE know that for Inductor X=2pifL,In DC f=0,then X=0 so,V=IX=0;But In the DC excitation of rotor of AC generator,DC motor field coil which coils are inductor so why does not applying DC voltage short the rotor coil of AC generator and field coil of motor?If it would then DC source might be damaged but it is not happened. Why does the strand conductor of Electrical power transmission line make twist?
PLZ EXPLAIN THE INTERLOCKING AND CONTROLLING OF CONTACTORS????HOW CAN I DO THAT?
What happened if C.T mount at any cable or Bus bar in wrong direction . C.T going on proper work or not . C,T direction is essential thing to properly work.
What is meant by Im=30mA@Vk/2. How to know the kee point voltage for CT design
WHAT IS counter flux IN CT?