Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how many by pass system in online UPS.

Answer Posted / shiv

There are two systems bypass one is auto and next is
manually.Which work the auto systems operate the self main
ups and manually not operate the non self so that any
costumer supporting the help.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is cable tray, its type, and its support?

1099


what you have to see after one week or month from the day of installation of transformer ?

1658


WHAT SHOULD BE THE BEST CURRENT RATINGS (PRIMARY / SECONDARY)FOR A CT INSTALLED AT THE INCOMING 11KV PANE? WILL IT BE CALCULATED ON THE BASES OF MAXIMUM DEMANT VALUE OR ON SUM OF ALL TRANSFORMER'S KVA? NOMALLY MAX DEMAND REPRESENT THE MAXIMUM OPERATING LOAD OF THE PLANT AND TOTAL KVA OF (SAY 5 NUMBERS TRANSFORMERS) REPRESENT THE CONNECTED LOAD. WHICH i.e. MAX DEMAND KVA OR CONNECTED KVA ARE BETTER TO USE FOR CT CURRENT CALCULATION? PLEASE ANSWER.

1850


I meggared my 2c*70 sq mm AL AR XLPE cable. its one end show 50 M ohm . is my cable is safe for laying. I have only one phase and neutral.

1801


why starting current is high and resistance is almost 0 during the starting of motor dc motor...?

1684


In 11/0.414 KV Parralel supply network with Bus tie closed what will be the fault level is it doubled or halved??

2032


What is creepage distance..... what will be the value for different voltage level

1925


What should be the magnetic balance test values for a 3 phase delta/star connected single primary dual secondary winding transformer (90 MVA / 2 X 45 MVA TRANSFORMER)

1847


Why a Permanent Magnet Generator has higher frequency as compared to frequency of main alternator?

1918


what is the difference between dry and wet type of 132kV terminations. which one is durable

1946


How to calculate the fuel consumption for 600kva DG genset which connecting with 25%load?

2074


How is the resonant peak, resonant frequency, and bandwidth determined from nichols chart?

1032


What are Contactors? How they works and what its highest rating?

2064


WHY NUTRAL GROUND SYSTEM USED IN 33KV SYSTEM

2171


what is Anti-pumping?

1886