Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

I have a table fan of Rallifan Make. When I overhauled it I
found a stator winding and an aluminum die cast rotor. So
it is supposed that it is a 1 phase induction motor. But
there are only two terminals coming out and there is no
capacitor. Can any one tell how this motor works? or which
type of this motor is?

Answer Posted / nvyibrahim

This is shaded pole motor.stator winding arrenged 90 degree
diffrence between rotor.

Is This Answer Correct ?    5 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How generator NPS(NEGATIVE PHASE SEQUENCE TEST)TEST WAS DONE? PROCEDURE WITH DETAILS?

2239


What is power factor why we should maintain the power factor unless what will happen

1918


List out the the types of Mounting Light fixture?

1615


Which device of PlC does share load between DG sets when DG are running in perallel?

2079


For electrical designers what are the standard should know? i want learn about this standards. how to get information/reference. anybody help in this regards please.

2145


234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,

2238


1.why we are using metal oxide gapless block in lightning arrester,2.What is minimum and maximum rating of metal oxide blocks using in india

1975


How to select HT/MV cable size ?

2474


can we do the star delta connection of capacitor for 3- phase motor starter.

2035


How to calculate size of HT breaker with the help of Amp (current)? Please provide answers with examples.

2337


What is sink and source?

1196


list the type of vfd? wich is sutable for heating kiln?

2105


can u describe the method used for protection of transmission line.

2226


Determine the BTU size of an aircon for 20 sq metre room