Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the difference between real and reactive power? and what is the importance of these

Answer Posted / ravi chaurasia

Real power is the power which is actually required to operate
the connected load in power sysyem.Reactive power is the
waste power from electricity board point of view but it is
the inherent requirement of the inductive loads.
In short it reduces the capacity of cables and transmission
line but is inherent requirement of the load.

Is This Answer Correct ?    4 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Dear sir, By which formula u can calculate for a particular kv line there is a range of mw.

2180


design of IGBT firing circuit for 11KV

2711


In power transmission using open belts or horizontal shafts it is preferable to have the slack side of the belt on the top because

1278


Usage of flywheel diode in relays

1991


what material is the electrical housing wire made of? is there any difference for the telephone lines?

2032


dear sir/madam i want to get some knowledge about RRB EXAMINATION(section engineer) 1- what is minimum cut off 2- wht portion is major portion . 3- can any body provide Sample paper. thanks & regards ashish

2413


Is a d.c.compound motor is use as a booster? how?

2187


Yazaki india pvt ltd interview questions qurey related

1082


difference bewteen reverse current and alternating current

2291


I am having a 42KW 3 phase electrical heating furnace, heating element is 80/20 nichrome material, my connections is made in such a way that 2 star connection compromising 2 coils per phase so totally 12 coils, shall if i use it unbalanced star condition (instead of 2 group of 3 phase or 1 group of 3 phase, connecting 4 phases of 5 phases) what will be the consequences and is it acceptable?

1724


how wecalculate breaking capcity of acb mcb mccb .explain with example

1986


what are the interview question asked in wind mill about electrical

2419


Which motor connection is preferable star-delta or delta-star?

1124


how we calculate the withstansing current capacity of wires&cables?

2053


how to calculate cooling requirement of datacentre from electrical load?

2483