when the instrument tapping on pipe line is located below
and transmitter is located above the tapping point for
liquid service transmitter, what should we do, is there any
additional drain valve is required??

Answer Posted / yanto

below tapping point is for liquid services and above tapping
is for gas services.

we do not need additional drain valve.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How d.p. Transmitter can be applied to close tank?

601


why using negative supply for bentley nevada vibration system ?

1704


we have level transmitter for h2s04 storage tank capacity 10k ,always there are failure of transmitter due to failure of magnetic floats ,please come up with solutions at the earliest.

1584


the whole paper was based on Transducers..questions like define repeatability, error,accuracy,precision..den there were many q. on the conversion of Pa to mmHg and other units.. also..der wer few Q. on some level sensors(with diagram)

1535


what is SIL 1 2 3

1535






1. For Steam drum level signal, why do we compensate with drum pressure signal? 2.For main steam Flow signal is comensated with main steam temperature signal and main steam pressure signal why?

1772


I want to buy a seal kit of a pneumatic power cylinder.But I don't know it's specification.So please help me to know its specification.

1496


how the arrangement of equipments done in control room

1586


What are the types of valves?

614


What is super thermocoupal?

1690


sir, give me placement papers and interview quistion of birla group company of copper.

2365


why we take %i0.0 as input for twido plc

1650


please tel me the calibration of pneumatic controler.

1717


Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =

1439


What is mean by analytical instrumentation?

1268