difference between brush less & brush excitation in a
generator?

Answer Posted / k.prakashchandra

Large gens have field as rotor and field supply is given
with the help of collector rings (slip ring) and carbon
brushes from shaft mounted DC exciter or external excitation
panel .In case of brushless, DC excitation supply is given
directly from shaft mounted armature of the AC exciter
through the rectifiers.Its field is controlled from outside.

Is This Answer Correct ?    1 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

we have 3 single phase transformers. how will we generate 6 supply from 3 phase supply input

1651


I want to know how to calculate the size of electricity cable in building?

1526


Who are the manufactures those manufacturing 3Cx2.5sqmm FRLS cables. I heard about FRLS technology adopted only in wires useful for wirings

1615


If we use 250A MCCB as a incomer in Control panel for a fault level of 50kA for one second ,assuming temperature rise from 85 Deg. to 100 Deg , Then what will be the Aluminium Bus-bar size for 250A MCCB? Explain in detail.

1833


what will happens if one phase is missing for 33/11kv power transfomer and why?

2181






why and where we use early make & late break contacts in protection?

7588


What is Control & Relay Panel? And Remote Control Center?

1734


one electromagnet is called

1420


why h parameter are called as hybrid parameter?

1538


my UPS suddenly goes off and all panel light also blow off.This happens even main electric supply is not interrupted.After some time it automatically starts functioning normally.Batteries are new.

1552


How efficiency of thermal plant can be improved?

747


What are the difference between normal application Transformer and Solar application Transformer?

1223


upto how much low RPM we will run the commercial motor which is run through VFD without any problem occurs in motor.Motor rating Duty is S1 & RPM is 1400.

1625


In our factory so many iron pillors are exists for supporting the shed/Hangar. If do more no of earthings at one piller instead of doing more earth pits in many locations and running earth strip around the hanger, I can save the money. Please suggest this method is acceptable as per Is specifications though the Earth resitance of the farthest piller is with in the limits as per IS specifications.

1641


I want to do a mini project. Now I'm studying in 6th semis tor EEE Engineering.

1662