An engineering term STALL used in compressor operation what
it means?
Answer Posted / sankar
Separation of the airflow from the suction surface of the fixed or rotating blades of a compressor. Any degree of stall reduces airflow.
Stall develops flow restriction and heat developed in compressor parts
| Is This Answer Correct ? | 2 Yes | 2 No |
Post New Answer View All Answers
please tell me what is a light up procedure of Cfbc boiler and what it's axuillaries of cfbc boiler?
Which type of pressure can be measured by primary elements?
How to Calibrate Vibration Probe (Axial, Redial) in field
Which are all the commonly used Bordon tubes in the pressure gauges. Do any one use ASTM A 312 tubes for this purpose?
1- Explain about HPM 2- What is the FSC and explain the configuration of FSC 3- explain the complete loop of vibration, how it works (field to control room) 4- What is the use of proxymitter? 5- During job your partner effected with H2S then what you have to do. 6- what type of gland packing uses when valve glind is leaking.
what is the reason while warning lamp is on while the engine is cranking?
Name different types of bourdon tubes.
give eg of how I/P is used in control loops
Speedtronic system .
how is work pressure switch& level switch?what is the principle of this?
How addressable fire systems work? Pl. send details with architect.(Loop), also send details regarding Gas system. Pl. help me.Thanks
In Safe Guarding test what means by "Failed to Danger" ?
Explain bernoulli’s theorem. State its application.
If fire would be inside the plant which fire detector is to detected the fire.
how to work MIL contol valve posistioner ?